Maintenance of marine batteries

Leave a message

The core of marine battery maintenance lies in daily inspection, charge and discharge management, environmental control, fault handling and storage management. The following are the specific operation points:

1. Daily inspection

Electrolyte management

Liquid level inspection: Check whether the electrolyte submerges the plate every month. If it is insufficient, add distilled water (tap water is prohibited). The liquid level must be kept 10-15mm above the plate.

Density detection: Use a densitometer to measure the specific gravity of the electrolyte. The density of the lead-acid battery should be 1.28-1.30g/cm³ when fully charged (the difference in a single cell should not exceed 0.05g/cm³). Abnormalities require balanced charging.

Terminal maintenance

Clean the pole oxide every quarter, apply anti-corrosion grease, and the tightening torque must meet the standard to avoid cracking caused by excessive force.
2. Charge and discharge management
‌Charging specification‌

Conventional charging adopts constant voltage and current limiting method, and the 12V system voltage is controlled at 14.4V±0.2V, and the current does not exceed 20% of the rated capacity.
‌Balanced charging‌: Charge the battery pack with a small current for a long time every month to balance the voltage difference of each battery (open circuit voltage difference ≤0.2V).
‌Discharge control‌

Avoid long-term undercharging or over-discharging to prevent plate sulfidation (manifested as capacity reduction and voltage abnormality).
3. Environmental control
‌Ventilation and heat dissipation‌: Keep the hydrogen concentration in the cabin below 4% and the temperature at 20-25℃; install a heat dissipation device at high temperature, and adjust the density of the low-temperature electrolyte to 1.30-1.32g/cm³.
‌Anti-vibration measures‌: Install rubber shock-absorbing pads, and the axial displacement is ≤1mm.
4. Fault handling
‌Plate sulfidation‌: If the capacity decay exceeds 20%, a small current of 0.02C can be used for desulfurization charging; if sulfidation is serious, the battery needs to be replaced.
‌Leakage treatment‌: Wear protective equipment, replace the shell after using sodium bicarbonate solution.
5. Storage management
‌Short-term outage‌ (1-3 months): Disconnect the load and recharge it monthly.
‌Long-term storage‌: Regularly float charge after full charge, keep in a dry and cool environment, and avoid vibration.